Problem:
One of our customers failed to calibrate the Xhorse Dolphin XP005L key cutting machine. The dolphin ii reported error code 6 during the calibration process.
Possible solution:
Open the back cover and adjust the X-axis sensor or baffle.
User feedback:
He checked and found this part is broken.
Final solution:
Need to replace the X-axis sensor.
Better replace the sensor of other axes to the X-axis and do an X-axis motor test first to see if there are any other problems.