7/24/2025

Xhorse Condor Motor Test Failed Error 55 Solution

 Here comes the solution to Xhorse Condor XC-Mini Plus or Condor II movement abnormal and error code 55 problem.


Xhorse Condor Motor Test Failed Error 55 error

Phenomenon: There is an abnormal noise when the X/Y/Z axis self checks and moves after Condor machine is turned on, Or there is abnormal noise when one of the X/Y/Z axis moves during the process of decoding or cutting keys;

 

Solution: Go to device self test – motor measurement- perform X/Y/Z motor testing separately (Refer to the following picture for the entry method)

Xhorse Condor Motor Test 1

Xhorse Condor Motor Test 2

Xhorse Condor Motor Test 3

Normal situation: ‘OK’ will be displayed at the bottom of the test interface, as shown in the picture;

Xhorse Condor Motor Test 4

Fault situation: A certain axis at the bottom of the interface will display ‘Bad’, indicating that there is a fault with this axis and the corresponding sensor needs to be replaced,

As indicated by the arrow on the right, it represents that there is a fault in the current Y-axis and the Y-axis sensor needs to be replaced;

Xhorse Condor Motor Test 5

Check

Xhorse Condor Motor Test 6

Xhorse Condor Motor Test 7

picture 1 shows the positions of Z-axis and Y-axis sensors;

picture 2 shows the appearance of the old sensor;

picture 3 shows the appearance of the new sensor.

If it is a fault with the X-axis sensor, please contact technical support as the steps for replacing the X-axis sensor are quite complicated.