5/08/2026

Xhorse Condor XC-009 Alignment Guide

Proper calibration ensures precision and extends tool life. Follow these steps to align your Xhorse Condor XC-009 before its first use or after mechanical impact. Ensure the power remains OFF throughout the entire procedure.

 

Preparation & Required Tools

Before beginning, verify that your work area is clean and you have the following tools from your kit:

  • Allen Wrenches: 5mm and 3mm hex keys included in your kit.
  • Calibration Gauges: Two standard gauges provided with the Condor XC-009
  • Flashlight: Highly recommended for verifying precise alignment in the jaw.

 

Step 1: Jaw and Gauge Setup

  1. Clean the Stopper: Ensure the key stopper is free of debris and perfectly straight.
  2. Set Jaw Position: Rotate both the left and right jaws to Side A.
  3. Install Gauges: Slide the gauges into the jaws until they hit the lip, hold them tight, and lock them down.

Xhorse Condor XC-009 Alignment  1

Xhorse Condor XC-009 Alignment 2

Xhorse Condor XC-009 Alignment 3

Step 2: Lateral (Horizontal) Adjustment

If the tracer does not align horizontally with the gauges:

  1. Unlock the Axis: Use the 3mm Allen wrench to unlock the lateral adjustment mechanism.
  2. Adjust Movement: Use the 2.5mm Allen wrench on the bottom of the unit to shift the guide until it slides smoothly into the gauge.
  3. Secure the Setting: Relock the adjustment screw once horizontal alignment is achieved.

Xhorse Condor XC-009 Alignment 4

Step 3: Depth (Micrometer) Fine-Tuning

  1. Release Top Lock: Slightly loosen the lock/unlock knob at the top of the machine.
  2. Dial the Micrometer: Turn the micrometer knob to adjust the depth.
  3. Control Direction: Turning the micrometer can push the guide out or draw it in for a tighter fit.
  4. Final Lock: Once the guide sits perfectly flush, lock the jaw and the top knob.

Xhorse Condor XC-009 Alignment 5

Xhorse Condor XC-009 Alignment 6

Step 4: Verification

  1. Shoulder Stop Check: Verify that the shoulder stop is functioning correctly and aligning with your gauges.
  2. Visual Inspection: Use a flashlight to confirm the tracers are properly seated in the gauges.

Xhorse Condor XC-009 Alignment 7

www.vvdishop.com

5/06/2026

How to Test Xhorse Dolphin XP005L Battery BMS Board?

Here comes the Xhorse Dolphin XP005L key cutting machine new style battery BMS board testing guide.

Test Xhorse Dolphin XP005L Battery BMS Board 1

Step 1: Short-circuit the switch,
Measure the voltage at Point a and Point c to verify if it is 5V.

Test Xhorse Dolphin XP005L Battery BMS Board 2

Test Xhorse Dolphin XP005L Battery BMS Board 3

Test Xhorse Dolphin XP005L Battery BMS Board 4

Step 2: Measure the voltage at Point 2 and Point 3 to verify if it is 24V.

Test Xhorse Dolphin XP005L Battery BMS Board 5

Test Xhorse Dolphin XP005L Battery BMS Board 6

Step 3: Disconnect the short-circuit interface and check if the voltage gradually drops to 0.

Test Xhorse Dolphin XP005L Battery BMS Board 7

Test Xhorse Dolphin XP005L Battery BMS Board 8

If all the above readings are correct, it indicates that the battery is in good condition; otherwise, please record a video for our technical team to perform a further diagnosis.

www.vvdishop.com