Here comes the solution to Xhorse Condor XC-Mini Plus II error code 6. Hope it helps if the same error occurs.

Solution:
When decoding or cutting keys by Condor 2, Error Code 6 indicates abnormal conductivity in the probe or cutter.
Follow the step-by-step guide below to solve it.
Step 1: Conductivity Test
Perform a conductivity measurement to diagnose the problem:
1.Navigate to Settings > Machine Test > Electrical Conductivity Measurement.



2.Follow the on-screen prompts to connect either the probe or cutter (not both).
3.Start the test.
Step 2: Test Results
If both the probe and cutter light up green simultaneously:
This indicates a short circuit between the probe and cutter.
Step 3: Inspect for Iron Filings
Check for iron filings around the three screws above the probe.

Clean the area thoroughly to remove all debris.
Step 4: Reinstall Screws
If the problem persists, remove the three screws above the probe.
Clean the area around the hole to ensure no iron filings remain.
Reinstall the screws, but:
Do not overtighten, as this can damage the insulation plastic ring on the screws, causing a short circuit.


Step 5: Check Conductive Wires
Restart the test. If the probe green light turns on before connecting:
- Indicates the probe is in a short circuit state.
Inspect the conductive wires on the probe disk for damage.
- Damaged wires should be wrapped with insulating tape.


Conclusion:
Retest conductivity using the Xhorse Condor XC Mini Plus II Key Cutting Machine’s test interface.
If the issue persists, consider replacing faulty components or contacting the manufacturer.