12/11/2024

Xhorse Condor II Error Code 6 Working Solution

 Here comes the solution to Xhorse Condor XC-Mini Plus II error code 6. Hope it helps if the same error occurs.

Xhorse Condor XC-Mini Plus II Error Code 6

Solution:

When decoding or cutting keys by Condor  2, Error Code 6 indicates abnormal conductivity in the probe or cutter.

Follow the step-by-step guide below to solve it.

Step 1: Conductivity Test

Perform a conductivity measurement to diagnose the problem:

1.Navigate to Settings > Machine Test > Electrical Conductivity Measurement.

Xhorse Condor XC-Mini Plus II Error Code 6 solution 1
Xhorse Condor XC-Mini Plus II Error Code 6 solution 2
Xhorse Condor XC-Mini Plus II Error Code 6 solution 3

2.Follow the on-screen prompts to connect either the probe or cutter (not both).

3.Start the test.

 

Step 2: Test Results

If both the probe and cutter light up green simultaneously:

This indicates a short circuit between the probe and cutter.

 

Step 3: Inspect for Iron Filings

Check for iron filings around the three screws above the probe.

Xhorse Condor XC-Mini Plus II Error Code 6 solution 4

Clean the area thoroughly to remove all debris.

 

Step 4: Reinstall Screws

If the problem persists, remove the three screws above the probe.

Clean the area around the hole to ensure no iron filings remain.

Reinstall the screws, but:

Do not overtighten, as this can damage the insulation plastic ring on the screws, causing a short circuit.

Xhorse Condor XC-Mini Plus II Error Code 6 solution 5
Xhorse Condor XC-Mini Plus II Error Code 6 solution 6

Step 5: Check Conductive Wires

Restart the test. If the probe green light turns on before connecting:

  • Indicates the probe is in a short circuit state.

Inspect the conductive wires on the probe disk for damage.

  • Damaged wires should be wrapped with insulating tape.

Xhorse Condor XC-Mini Plus II Error Code 6 solution 7
Xhorse Condor XC-Mini Plus II Error Code 6 solution 8

Conclusion:

Retest conductivity using the Xhorse Condor XC Mini Plus II Key Cutting Machine’s test interface.

If the issue persists, consider replacing faulty components or contacting the manufacturer.

 

www.vvdishop.com

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.